Lead acid battery msds pdf potassium

Components are for a fully charged lead acid design. May cause severe irritation of the mouth, throat, esophagus, and stomach. Avoid contact with strong acids, bases, halides, halogenates, potassium nitrate, permanganate, peroxides, nascent hydrogen and reducing agents. Seek immediate medical attention if eyes have been exposed directly to. Advice to doctor treatment for sulfuric acid and lead. Precautions for use exposure standard workplace exposure standard for metallic lead is 0. Valve regulated maintenance free lead acid gel batteries contd. Avoid contact with strong acids, bases, halides, halogenates, potassium nitrate. The australian dangerous goods code defines battery transport requirements in australia. May cause abdominal pain, nausea, vomiting, diarrhea, and severe cramping. Hands contaminated by contact with internal components of a battery can cause ingestion of leadlead compounds. Possible erosion of tooth enamel, inflammation of nose, throat and bronchial tubes.

Misuse of the product, such as overcharging, may result in the generation of sulfuric acid mist. Potassium, carbides, sulfides, peroxides, phosphorus, sulfurs, ketone, ester, petrolatum. Inorganic acid mist sulfuric acid mist is not generated under normal use of this product. Lead 7439921 3060% sulfuric acid 7664939 2040% lead dioxide 9600 1030% percentages of components are dependent on both the model of the rbc and the state of chargedischarge of the battery. Material safety data sheet nonspillable lead acid battery chemtrec domestic. Lead is listed as a 2b carcinogen, likely in animals at extreme doses. Other ingredients may be pr esent dependent upon battery type. Acid mist generated during battery charging or spillage of the electrolyte in a confined area may cause respiratory irritation. Do not fill cells with lead acid battery electrolyte. Exposure to lead from a battery most ofte n occurs during lead reclaiming operations through the breathin g of or ingestion of lead dusts and fumes. Acute ingestion may cause abdominal pain, nausea, vomiting, diarrhea and severe cramping.

Acid can be release if the battery case is damaged or if the vents are tampered with. Under severe exposure emergency conditions, wear acidresistant clothing and. Safety data sheet valve regulated lead acid batteries. Batteries also contain other chemicals known to the state of california to cause cancer. Industrial lead acid battery safety data sheet date. These features, along with their low cost, make them attractive for use in. Silicon dioxide gel batteries only 7631869 15 sheet molding compound glass reinforced polyester inorganic lead and electrolyte sulfuric acid are the primary components of every battery manufactured by enersys. Industrial lead acid battery safety data sheet northstar battery.

Material safety data sheet lead acid battery wet, nonspillable. Product identification product name lead acid battery, wet other names batteries, wet, filled with acid, electric storage, use automotive, industrial standby power and motive power. Inorganic lead and electrolyte water and sulfuric acid solution are the primary components of every battery manufactured by exide technologies or its subsidiaries. Contact of acid with metals may produce sulfur dioxide fumes and hydrogen gas. Do not allow discharge of unneutralized acid to sewer. Wear acid resistant clothing, boots, gloves, and face shield. Wear acidresistant clothing, boots, gloves, and face shield.

Lead acid battery wet, filled with acid us, cn, eu version for international trade section 1. Reproductive toxicity battery posts, terminals and related accessories contain lead and lead compounds. Inorganic lead and electrolyte sulfuric acid are the primary components of. The johnson controls sealed cellbattery is considered an article as. Despite having a very low energytoweight ratio and a low energytovolume ratio, its ability to supply high surge currents means that the cells have a relatively large powertoweight ratio. Do not storeoperate the nickel cadmium batteries in the same room where the lead acid batteries are stored operated. Material safety data sheet storage battery systems. Lead acid battery wet, filled with acid other product names. Flush immediately with large amounts of water for at least 15 minutes while lifting lids. Steel fe 1025 polypropylene 811 potassium hydroxide 5. Exposure to lead from a battery most often occurs during lead reclaim operations through the breathing or ingestion of lead dusts and fumes.

Engineering controls use only in a well ventilated area. Acrylonitrile butadine styrene abs 9003569 510% na na na inorganic lead and electrolyte sulfuric acid are the main components of every valve regulated lead acid battery supplied by powersonic corporation. Inorganic lead and electrolyte sulfuric acid are the primary components of every. In high temperature conditions, contact with strong acid or base or in the presence of hydrogen gas, highly toxic arsine gas may be produced sulfuric acid component of battery may produce hazardous gases such as sulfuric cid mist. Do not allow smoking, open flame or sparks near batteries while charging. Safety data sheet lead acid battery wet, filled with acid. Misuse of the product, such as overcharging, may however result in the generation of sulfuric acid mist.

Contact with the electrolyte will cause burns to the eyes and skin. Polypropylene is the principa l case material of automotive and commercial batteries. Safety data sheet lead acid battery, wet, filled with acid document sds01897 rev no. If battery case is damaged wear rubber or plastic acid resistant gloves with elbow length gauntlet, acid. Hands contaminated by contact with internal components of a battery can cause ingestion of lead lead compounds. Safety data sheet lead acid battery, wet, nonspillable document sds01898 rev no. Avoid contact with strong bases, acids, combustible organic materials, halides, halogenates, potassium nitrate, permanganate, peroxides. Under severe exposure emergency conditions, wear acid resistant clothing and. An explosive hydrogenoxygen mixture may occur during charging. Industrial battery, traction battery, stationary battery. Workplace exposure standard for sulphuric acid is 1 mgm 3 in air.

Avoid contact with strong acids, bases, haliders, halogenates, potassium. Product identification manufacturersupplier exide technologies 00 deerfield parkway, bldg. Hazardous label inorganic leadlead compounds 7439921 72% t sulfuric acid 7664939 20% c fiberglass separator 65997173 2% silicon dioxide gel batteries only 7631869 10% of acid wt. Page 46 safety data sheet according to safe work australia printing date. Product and company identification interstate allbattery emergency phone. Ascent battery supply, llc makes no warranty or merchantability or any other warranty, express or implied, with. Ascent battery supply, llc 25 walnut ridge drive hartland, wi 53029 safety data sheet sds sealed lead acid. If battery case is damaged, use chemical goggles or face shield. Lead acid storage battery superior battery mfg co, inc page 2 of 3 msdswhmis issue date. Powersonic msds page 3 of 6 continued on next page ingestion sulfuric acid. Lead acid battery wet, filled with acid us, cn, eu version for international trade. Avoid contact with strong acids, bases, halides, halogenates, potassium. Electric storage battery, sli or industrial battery, un2794 manufacturer. Material safety data sheet for sealed lead acid batteries this msds applies to all interstate batteries and power patrol batteries that are sealed leadacid batteries including but not limited to those with part numbers starting with sla and dcm.

May cause severe irritation of mouth, throat, esophagus and stomach. In areas where sulfuric acid is handled in concentrations greater than 1%, emergency eyewash stations and showers should be provided, with unlimited water supply. Material safety data sheet powerizer battery official site. Common names starting lighting ignition sli battery. Battery, wet, nonspillable absorbed glass mat agm battery sealed leadacid sla battery. Ingestion of sulfuric acid will cause gi tract burns. Valve regulated leadacid rechargeable battery, maintenance free battery ingredient cas no. Battery posts, terminals, and related accessories contain lead and lead compounds, chemicals known to the state of california to cause cancer and reproductive. Ingestion of battery electrolyte will cause severe burns to mouth and gastrointestinal tract.

Lead components of battery may produce toxic metal fume, vapor or dust. Avoid contact with strong acids, bases, halides, halogenates, potassium nitrate, permanganate, peroxides, nascent hydrogen, and reducing agents. If battery case is damaged wear rubber or plastic acidresistant gloves with elbow length gauntlet, acid. Material safety data sheet batteries, wet, filled with acid. Gel the information and recommendations below are believed to be accurate at the date of document preparation. Dilute sulfuric acid 7664939 1420% fiberglass separator 5% na na na case material. Partition coefficient noctanolwater not applicable. This product is considered a hazardous substance, preparation or. Hazardous exposure can occur only when product is heated, oxidized or otherwise processed.

Wear acid resistant beets, faceshield, chemical splash genltals, and acid resistant gloves. Contact with combustibles and organic materials may cause fire and explosion. In high temperature conditions, contact with strong acid or base or in the presence of hydrogen gas, highly toxic arsine gas may be produced sulfuric acid component of battery may. Revised march 15, 2011 general information item name. In case of damage resulting in breakage of the battery container, see viii, sec. Wear acidresistant beets, faceshield, chemical splash genltals, and acid resistant gloves. Avoid contact between lead compounds and strong acids, bases, halides, potassium nitrate, permanganate, peroxides and reducing agents. Jan 2007 inhaled sulfuric acid remove to fresh air immediately. Lead direct skin or eye contact may cause local irritation. Do not store any other material on top of the batteries. Contact with acid can cause severe burns on the skin and in the eyes. Acdelco lead acid battery, wet conventional print date. Other ingredients may be present dependent upon battery type.